subject
Engineering, 18.07.2019 20:30 eks8252

Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.128 kg/s, and it leaves at 0.7 mpa and 50°c. the refrigerant is cooled in the condenser to 24°c and 0.65 mpa, and it is throttled to 0.15 mpa. disregarding any heat transfer and pressure drops in the connecting lines between the components determine (a) the rate of heat removal from the refrigerated space and the power input to the compressor kw (round to one decimal place) kw (round to two decimal places) in (b) the isentropic efficiency of the compressor, % (round to one decimal place) and (c) the cop of the refrigerator cop round to two decimal places)

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Slip occurs via two partial dislocations because of (a) the shorter path of the partial dislocation lines; (b) the lower energy state through partial dislocations; (c) the charge balance.
Answers: 1
question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:20
A2-m rigid tank initially contains saturated water vapor at 100 kpa. the tank is connected to a supply line through a valve. steam is flowing in the supply line at 600 kpa and 300 c. the valve is opened, and steam is allowed to enter the tank until the pressure in the tank reaches the line pressure, at which point the valve is closed. a thermometer placed in the tank indicates that the temperature at the final state is 200°c. determine (a) the mass of steam that has entered the tank (b) the amount of heat transfer.
Answers: 3
question
Engineering, 04.07.2019 19:20
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
You know the right answer?
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c...
Questions
Questions on the website: 13722361