There is a vapor compression type refrigeration cycle using the refrigerant hfc 134 a. in the condenser, it is isostatically cooled, the condensation temperature is 50 ° c., and the condenser outlet is the compressed liquid at 45 ° c. in the evaporator, it is isothermally heated, the evaporation temperature is 10 ° c. and the outlet of the evaporator is heated steam at 15 ° c. when the expansion valve performs isenthalpic expansion, and the adiabatic efficiency of the compressor is 0.70, answer the following questions. (a) calculate the specific enthalpy of the compressor outlet temperature, specific enthalpy, condenser outlet and evaporator outlet. (b) obtain the cooling operation coefficient of this system. (c) obtain the circulation amount of the refrigerant necessary for obtaining the cooling effect of 3.0 kw in this system.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
If you were designing a bumper for a car, would you prefer it to exhibit elastic or plastic deformation? why? consider the functions of a bumper in both a minor "fender-bender" and a major collision.
Answers: 1
question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk