subject
Engineering, 20.08.2019 17:30 monserratmendezca20

Amixing chamber operating at steady state at 100 kpa receives a saturated liquid-vapor mixture of water at a first inlet at 0.8 kg/s and a quality of 0.9, steam enters at a second inlet at 2 kg/s and 200°c, and liquid water enters at a third inlet at 1.2 kg/s and 95°c. all h2o leaves through a single exit at 100 kpa. unfortunately, the insulation fell off part of the mixing chamber, so heat is lost from the chamber at a rate of 60 kw. a. determine the mass flow rate of the stream leaving. b. determine the temperature of the stream leaving. c. draw the four state points on a t-v diagram. d. draw the four state points on a p-v diagram. e. determine the temperature of the stream leaving if the insulation is fixed.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Inspection for bearing condition will include: (clo4) a)-color b)-smell c)-size d)-none of the above
Answers: 1
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 19:10
When subject to a steady load (within elastic range) over a long period of time, what is the major difference in material behavoir between steel and plastic?
Answers: 2
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
Amixing chamber operating at steady state at 100 kpa receives a saturated liquid-vapor mixture of wa...
Questions
question
English, 23.06.2019 02:20
question
Mathematics, 23.06.2019 02:20
question
Mathematics, 23.06.2019 02:20
question
Chemistry, 23.06.2019 02:20
Questions on the website: 13722362