Acomputer terminal room contains 125 computers with a power consumption of 130w. the room is well-insulated so that only 25% of the energy generated by the computers and their operators is dissipated through the walls. the room is 15 x 40 m with a 2.5m high ceiling and the ventilation system changes 0.9m/s resulting in a net energy flow 20kj/m. calculate the temperature of the air in the room at 10am if all of the computers are used continuously by operators with a metabolic output 85w from 9am when the temperature was 18°c. assume the specific gas constant and specific heat capacity for air are 287 j/kg. k and 1.005 kj/kg. k respectively and that atmospheric pressure is 101bar.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:20
Apiston-cylinder device contains 0.1 m3 of liquid water and 0.9 m3 of water vapor in equilibrium at 800 kpa. heat is transferred at constant pressure until the temperature of water reaches 350 °c. determine (a) the quality of water at the initial state (b) the work associated with this process, (c) the heat associated with this process.
Answers: 2
question
Engineering, 04.07.2019 19:20
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
You know the right answer?
Acomputer terminal room contains 125 computers with a power consumption of 130w. the room is well-in...
Questions
question
Mathematics, 25.04.2021 04:10
question
Mathematics, 25.04.2021 04:10
Questions on the website: 13722366