subject
Engineering, 24.08.2019 02:10 emilyplays474

Arefrigeration plant operates in pretoria on refrigerant r134a at an evaporator pressure of 105 kpa (gauge) and a condensing pressure of 920 kpa (gauge). there is a sub-cooling of 3 k with a superheat of the gas entering the compressor of 8 k. the compressor is a four-cylinder reciprocating compressor with a bore of 67 mm and a stroke of 57 mm with an estimated capacity of 35 kw. the compressor is directly coupled to an electric motor running at 1470 rev/min and a power consumption of 19,5 kw. calculate: (a) the clearance volume efficiency if the compressor clearance is 3,6 %; (b) the actual volumetric efficiency; (c) the compression efficiency when the mechanical efficiency is 85% and the motor efficiency 90%.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
question
Engineering, 04.07.2019 18:10
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
You know the right answer?
Arefrigeration plant operates in pretoria on refrigerant r134a at an evaporator pressure of 105 kpa...
Questions
question
Mathematics, 05.02.2020 12:04
question
Mathematics, 05.02.2020 12:05
Questions on the website: 13722359