subject
Engineering, 31.08.2019 05:30 cat20220

An operating theatre is maintained at an inside temperature of 26°c dry-bulb when the outside air is at 40°c dry-bulb, 22°c wet-bulb and the sensible and latent heat gains in the operating theatre are 9 kw and 3 kw, respectively. a 100 per cent fresh air is handled, the air temperature leaving the cooling coil being 14°c and the apparatus dewpoint 12°c. assume a rise of 1.5°c across the supply fan (which is located after the cooling coil) and a further rise of 2°c because of heat gains to the supply duct. show the psychrometric processes on the psychrometric chart and determine (a) the shf (sensible heat factor) in the theatre (b) the wet bulb temperature of the supply air just after the cooling coil (c) the relative humidity of the air maintained in the theatre. (d) mass flow rate of supply air required (e) the cooling load of the cooling coil

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 04.07.2019 12:10
On a average work day more than work place firs are reorted
Answers: 1
question
Engineering, 04.07.2019 16:10
An electrical motor raises a 50kg load at a construct velencity .calculate the power of the motor, if it takes 40sec to raise the load through a height of 24m(take g =9.8n/g)
Answers: 2
You know the right answer?
An operating theatre is maintained at an inside temperature of 26°c dry-bulb when the outside air is...
Questions
question
Mathematics, 04.03.2021 23:20
question
Law, 04.03.2021 23:20
question
Mathematics, 04.03.2021 23:20
question
Mathematics, 04.03.2021 23:20
question
Mathematics, 04.03.2021 23:20
Questions on the website: 13722363