Engineering, 06.09.2019 17:10 travisvb

Ahydronic system is proposed for a 20-story building, with the chilled water pump located on the lowest floor and makeup water at the top floor. each story is 15 ft (4.6 m), and the makeup water pressure is 15 psi (103 kpa). the main air handlers are located on the top floor, and a variety of terminal units on each floor. the total piping friction loss is 60 ft of head (179 kpa). what is the static head of the chilled water system at the pump while turned off? 75 psi (517 kpa) a. b. 115 psi (793 kpa) c. 145 psi (1000 kpa)

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
Ahydronic system is proposed for a 20-story building, with the chilled water pump located on the low...
Questions
question
Mathematics, 01.04.2021 05:00
question
Mathematics, 01.04.2021 05:00
question
Mathematics, 01.04.2021 05:00
question
Mathematics, 01.04.2021 05:00
Questions on the website: 13722367