subject
Engineering, 15.10.2019 19:00 paulitaaustin

The affan industry has a 240v supply from which the following load are taken;
four hundred 150w lamp, three hundred 100w lamp, five hundred 80w lamp, two hundred 120w lamp and one hundred 60w lamp.
computer three 400w, 100kw and 1000kw.
air conditioner a total of 597kw.
photocopying machines 1000kw.
electric typewriter ten 500w.
assuming that the lighting load is on for a period of 6hours/2days the computer for 3hours per day, the air conditioner for 48hours per 24days, the photocopying machine for 48hours per day and the electric typewriter for 4hours per day calculate;
1. the weekly consumption of the industry in key when working on a 7days week.
2. what current is taken the computer load only if switched on?
3. if the affan add ten automatic voltage to his industry each taken a current of 4a, calculate the weekly consumption of the industry in kwh when working on a 5 day week. assuming that the load is on for a period of unity hour per day.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
question
Engineering, 04.07.2019 18:20
Vibration monitoring this technique uses the noise or vibration created by mechanical equipment and in seme cases by plant systems to detemine their actual condtion. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:20
Aquick transition of the operating speed of a shaft from its critical speed will whirl amplitude. (a) increase (b) limit (c) not affect (d) zero
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
The affan industry has a 240v supply from which the following load are taken;
four hundred 150...
Questions
question
Mathematics, 23.07.2019 23:30
question
Mathematics, 23.07.2019 23:30
question
Biology, 23.07.2019 23:30
Questions on the website: 13722363