subject
Engineering, 16.10.2019 02:10 cupcake3103670

For the following cantilever slab, use concrete with a compressive strength of 7,000 psi and grade 60 steel bars. (a) check if the design meets the requirements enforced by aci 318-14 in terms of the slab thickness, minimum reinforcement, spacing, and cover. (b) regardless of your findings from the first part, obtain the nominal strength and design strength of the slab. (c) determine the maximum surface live load that the slab can sustain.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
The thermal expansion or contraction of a given metal is a function of the f a)-density b)-initial temperature c)- temperature difference d)- linear coefficient of thermal expansion e)- final temperature f)- original length
Answers: 2
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
question
Engineering, 05.07.2019 04:30
Technician a says that in a worm gear steering system, most excessive steering free play is usually found in the gearbox. technician b says that in a rack-and-pinion steering system, excessive free play can be found in the bushings. who is correct?
Answers: 2
You know the right answer?
For the following cantilever slab, use concrete with a compressive strength of 7,000 psi and grade 6...
Questions
question
Spanish, 15.01.2021 02:10
question
Mathematics, 15.01.2021 02:10
question
Chemistry, 15.01.2021 02:10
question
Mathematics, 15.01.2021 02:10
question
Mathematics, 15.01.2021 02:10
question
Mathematics, 15.01.2021 02:10
question
Mathematics, 15.01.2021 02:10
question
Mathematics, 15.01.2021 02:10
question
Mathematics, 15.01.2021 02:10
question
Mathematics, 15.01.2021 02:10
Questions on the website: 13722363