subject
Engineering, 18.10.2019 18:20 lexas7961

Asingle phase, 50 kva, 2400/240 v, 60hz, distribution transformer is used as a step down transformer at the load end of a 2400 v feeder whose series impedance is (1.0 +j2.0) ohms. the equivalent series impedance of the transformer is (1.0 +j2.5) ohms referred to the high side. the transformer is delivering rated load at 0.8 power factor leading and at rated secondary voltage. neglecting the transformer exciting current. determine following:

1. the voltage at the transformer primary terminals
2. the voltage at the sending end of the feeder
3. the real and reactive power delivered to the sending end of the feeder

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Aplate clutch has a single pair of mating friction surfaces 250-mm od by 175-mm id. the mean value of the coefficient of friction is 0.30, and the actuating force is 4 kn. a) find the maximum pressure and the torque capacity using the uniform-wear model. b) find the maximum pressure and the torque capacity using the uniform-pressure model.
Answers: 3
question
Engineering, 04.07.2019 18:10
Journeyman training is usually related (clo2) a)-to specific tasks b)-to cost analysis of maintenance task c)-to control process to ensure quality d)-to installation of machinery
Answers: 2
question
Engineering, 04.07.2019 19:10
Air inially occupying a volume of 1 m2 at 100 kpa, 27 c undergoes three internally reversible processes in series. process 1-2 compression to 500 kpa during which pv constant process 2-3 adiabatic expanslon to 100 kpa process 3-1: constant-pressure expansion to 100 kpa (a) calculate the change of entropy for each of the three processes. (b) calculate the heat and work involved in each process. (c) is this cycle a power cycle or refrigeration cycle?
Answers: 3
You know the right answer?
Asingle phase, 50 kva, 2400/240 v, 60hz, distribution transformer is used as a step down transformer...
Questions
question
Mathematics, 16.10.2020 15:01
question
Social Studies, 16.10.2020 15:01
Questions on the website: 13722362