subject
Engineering, 25.10.2019 18:43 Pen350

Adisplacement transducer has the following specifications: linearity error ± 0.25% reading drift ± 0.05%/○c reading sensitivity error ± 0.25% reading excitation 10 – 25 v dc output 0 – 5 v dc range 0 – 5 cm the transducer output is to be indicated on a voltmeter having a stated accuracy of ± 0.1% reading with a resolution of 10 μv. the system is to be used at room temperature, which can vary by ±10○c. estimate an uncertainty in a nominal displacement of 2 cm at the design stage. assume 95% confidence. assume sensitivity is k = 1 v/cm

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Carbon dioxide gas expands isotherm a turbine from 1 mpa, 500 k at 200 kpa. assuming the ideal gas model and neglecting the kinetic and potential energies, determine the change in entropy, heat transfer and work for each kilogram of co2.
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
You know the right answer?
Adisplacement transducer has the following specifications: linearity error ± 0.25% reading drift ±...
Questions
question
Spanish, 07.05.2021 23:50
question
Mathematics, 07.05.2021 23:50
Questions on the website: 13722360