subject
Engineering, 30.10.2019 23:31 tinamarie04ts

Amodel of a high-rise office building at 1/550 scale is tested in a wind tunnel to estimate the pressures and forces on the full-scale structure. the wind-tunnel air speed is 20 m/s at 20°c and atmospheric pressure, and the full-scale structure is expected to withstand winds of 200 km/h (10°c). if the extreme values of the pressure coefficient are found to be 1.0, –2.7, and –0.8 on the windward wall, side wall, and leeward wall of the model, respectively, what corresponding pressures could be expected to act on the prototype? if the lateral wind force (wind force on building normal to wind direction) was measured as 20 n in the model, what lateral force might be expected in the prototype in the 200 km/h wind?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
question
Engineering, 04.07.2019 18:20
Prove the equivalence between the two statements of the 2nd law of thermodynamics (i.e., a violation of one statement leads to the violatio the other statement)
Answers: 2
question
Engineering, 04.07.2019 18:20
Atank with constant volume contains 2.27 kg of a mixture of water phases (liquid-vapor). in the initial state the temperature and the quality are 127 °c and 0.6, respectively. the mixture is heated until the temperature of 160 oc is reached. illustrate the process in a t-v diagram. then, determine (1) the mass of the vapor in kg at the initial state, (2) the final pressure in kpa.
Answers: 3
You know the right answer?
Amodel of a high-rise office building at 1/550 scale is tested in a wind tunnel to estimate the pres...
Questions
question
Mathematics, 27.04.2021 21:10
question
Mathematics, 27.04.2021 21:10
question
Mathematics, 27.04.2021 21:10
question
Mathematics, 27.04.2021 21:10
Questions on the website: 13722363