subject
Engineering, 18.11.2019 23:31 maddiemccarter3892

In fracas failure trend analysis, match these findings with their probable root cause (some may be used more than once, and some may not be used): different components from the same vendor fail in different applications. design issue. b. manufacturing workmanship or process issue. isame component, possibly from different vendors, fails, but in the same location (on a circuit card, for example). c. wearout issue a component seems to fail, but when the component is removed and tested, it tests ok dvendor process or vendor quality issue. failure only happens during certain conditions (such as environmental)

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:20
Select any two (2) areas of applications of chain-drive. (clo4) a)-permanent lubrication necessary b)-hydraulic forklift truck operation c)-rigging and heavy moving materials d)-relatively high maintenance costs e)-costlier than belt drives
Answers: 2
question
Engineering, 04.07.2019 18:20
Determine the damped natural frequencies and the steady state response of a decoupled damped forced two degrees of freedom system. 10ä1 + 2q1 20q1 10 cos t; 10q2 +4q2 + 40q2 10 cos t
Answers: 3
You know the right answer?
In fracas failure trend analysis, match these findings with their probable root cause (some may be u...
Questions
question
Geography, 11.10.2020 08:01
question
Mathematics, 11.10.2020 08:01
question
Social Studies, 11.10.2020 08:01
question
Biology, 11.10.2020 08:01
question
Mathematics, 11.10.2020 08:01
question
Mathematics, 11.10.2020 08:01
question
Physics, 11.10.2020 08:01
Questions on the website: 13722361