subject
Engineering, 19.11.2019 01:31 sdoty7702

Agreet function that accepts another godzilla object as a parameter which is passed by constant reference. that is, the parameter should be marked constant so that the function cannot inadvertantly change the target's values. the function should print out a message in the form of "callee's name bows to target's name." now in main before the two godzillas do battle, have godzilla greet mechagodzilla. as in, the code would look like godzilla. greet( mechagodzilla ); in order for this to work, you will need to make sure that you have marked all of your functions as const or not appropriately. which functions should be constant functions? which parameters should be constant parameters?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
You know the right answer?
Agreet function that accepts another godzilla object as a parameter which is passed by constant refe...
Questions
question
Computers and Technology, 28.08.2019 14:00
question
Social Studies, 28.08.2019 14:00
question
Mathematics, 28.08.2019 14:00
question
Mathematics, 28.08.2019 14:00
Questions on the website: 13722367