subject
Engineering, 21.11.2019 03:31 paige1616

Arod of diameter d=25mm and thermal conductivity k=60w/(m*k) protrudes normally from a furnace wall that is at tw=200°c and is covered by insulation of thickness lins=200mm. the rod is welded to the furnace wall and is used as a hanger to support instrumentation cables. to avoid damaging the cables, the temperature of the rod at its exposed surface, to, must be maintained below a specified operating limit of tmax=100°c. the ambient air temperature is 30°c, and the convection coefficient is 17.0 w/(m2*k). a) derive an expression for the exposed surface temperature, to, as a function of the prescribed thermal and geometrical parameters. the rod has an exposed length lo, and the tip is well insulated. b) will a rod of length lo=180mm meet the specified operating limit? if not, which design parameters would you change? note the variables and whether increasing or decreasing them would change to.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The drive force for diffusion is 7 fick's first law can be used to solve the non-steady state diffusion. a)-true b)-false
Answers: 1
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
You know the right answer?
Arod of diameter d=25mm and thermal conductivity k=60w/(m*k) protrudes normally from a furnace wall...
Questions
question
Law, 10.12.2020 14:00
question
Spanish, 10.12.2020 14:00
question
History, 10.12.2020 14:00
question
History, 10.12.2020 14:00
question
English, 10.12.2020 14:00
question
Mathematics, 10.12.2020 14:00
question
Health, 10.12.2020 14:00
question
Mathematics, 10.12.2020 14:00
Questions on the website: 13722361