subject
Engineering, 28.11.2019 05:31 devoncruz23

In a dairy operation, milk at a flow rate of 250 liter/hour and a cow body temperature of 38.6 degree c must be chilled to a safe-to-store temperature of 13 degree c or less. ground water at 10 degree c is available at a how rate of 0.72 m^3/h. the density and specific heat of milk are 1030 kg/m^3 and 3860 j/kg k, respectively, determine the outlet temperature of the water. determine the ua product of a counterflow heat exchanger required for the chilling process. determine the length of the exchanger if the inner pipe has a 50-mm diameter and the overall heat transfer coefficient is u = 1000 w/m^2 k. using the value of ua found in part (a), determine the milk outlet temperature if the water flow rate is doubled. what is the outlet temperature if the flow rate is halved?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 18:20
Acertain flow of air (at stp) has a velocity distribution given by v i (in ft/s). if this flow is going through a 4 ft square area in the yz-plane (centered at the origin), what is the mass flow rate (in lbm/s)?
Answers: 2
You know the right answer?
In a dairy operation, milk at a flow rate of 250 liter/hour and a cow body temperature of 38.6 degre...
Questions
question
History, 14.04.2021 20:50
question
English, 14.04.2021 20:50
question
Business, 14.04.2021 20:50
question
Mathematics, 14.04.2021 20:50
question
Mathematics, 14.04.2021 20:50
Questions on the website: 13722362