Acovered steel (unit weight = 500pcf) tank, 45ft inside diameter × 30ft high and with 0.75in. wall thickness, is filled with liquid (unit weight = 60pcf) up to a height of 29.5ft. the tank sits on a concrete (unit weight = 150pcf) foundation of diameter 46ft and thickness of 2ft. the foundation bottom is 2ft below the finished surface elevation. the soil consists of 10ft thick soft, normally consolidated marine clay above a very thick layer of gravel (> 30ft thick). the geotechnical data of the clay are cc = 0.52, cr = 0.08, cv = 0.08ft2 /year, and w = 48%. the groundwater level is 2ft below the surface. assume that the foundation is flexible and that the soil above the groundwater level is saturated.(a) make a sketch of the soil profile with the tank resting on its foundation.(b) calculate the primary consolidation settlement under the center of the completely filled tank.(c) calculate the times for 50% and 100% consolidation to occur.(d) calculate the primary consolidation settlement if the tank was loaded to half its capacity and kept there for 2 years.(e) calculate the rebound if the tank is now completely emptied.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The filament of an incandescent lamp has a temperature of 2000k. calculate the fraction of radiation emitted in the visible light band if the filament is approximated as blackbody
Answers: 2
question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
Acovered steel (unit weight = 500pcf) tank, 45ft inside diameter × 30ft high and with 0.75in. wall t...
Questions
question
Mathematics, 06.05.2021 18:50
question
Mathematics, 06.05.2021 18:50
question
Computers and Technology, 06.05.2021 18:50
question
History, 06.05.2021 18:50
question
English, 06.05.2021 18:50
Questions on the website: 13722363