Air enters a two-stage compressor at 1 atm and 27c and is compressed to 15 atm such
that...
Engineering, 30.11.2019 03:31 Vauzh
Air enters a two-stage compressor at 1 atm and 27c and is compressed to 15 atm such
that the pressure ratio across the first stage is 5. the steady mass flow rate is 0.2 kg/s.
between the two stages, the air is cooled at constant pressure to 57c. assume that the
compression process is isentropic. illustrate the process on p ? v and t ? s diagrams.
a) determine the power input to the compressor.
b) determine the rate of heat rejection during the cooling process and calculate the
associated rate of entropy change.
c) how much compressor power would be required for a single stage compression to 15
atm?
d) how much compressor power would be required if the single stage compression to 15
atm occured isothermally?
Answers: 2
Engineering, 04.07.2019 18:10
Afluid flows with a velocity field given by v=(x/t)i.. determine the local and convective accelerations when x=3 and t=1.
Answers: 2
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
Engineering, 04.07.2019 18:20
Select any two (2) areas of applications of chain-drive. (clo4) a)-permanent lubrication necessary b)-hydraulic forklift truck operation c)-rigging and heavy moving materials d)-relatively high maintenance costs e)-costlier than belt drives
Answers: 2
Engineering, 04.07.2019 19:10
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces.a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
Geography, 26.09.2019 18:30
History, 26.09.2019 18:30
Biology, 26.09.2019 18:30
History, 26.09.2019 18:30
Health, 26.09.2019 18:30
Mathematics, 26.09.2019 18:30
Mathematics, 26.09.2019 18:30
English, 26.09.2019 18:30
Mathematics, 26.09.2019 18:30
Mathematics, 26.09.2019 18:30
Spanish, 26.09.2019 18:30