subject
Engineering, 03.12.2019 22:31 alexisbrad3107

Design the flexural reinforcement of a tied column in a reinforced concrete frame is subjected to the following loading scenarios: a. pd = 240 kips, md = 140 k-ft, pl = 160 kips, ml = 300 k-ft b. pd = 200 kips, md = 140 k-ft, pl = 140 kips, ml = 220 k-ft c. pd = 300 kips, md = 120 k-ft, pl = 300 kips, ml = 200 k-ft d. pd = 380 kips, md = 130 k-ft, pl = 265 kips, ml = 180 k-ft e. pd = 220 kips, md = 140 k-ft, pl = 140 kips, ml = 220 k-ft in your design use concrete with compressive strength of 4,000 psi and grade 60 steel bars. (hint: initially consider the maximum axial load demand. after determining the column dimensions, check for all cases to find the required reinforcement ratio.)

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Ifa component is made of two or more materials with different modulus of elasticity (e), it is called a composite member and we calculate the factor·n". mention the formula for calculating n". also, ifn> 1, explain what will happen to the 1. transformed.gi) ifn 1, what will happen to the material when transformed material when
Answers: 1
question
Engineering, 04.07.2019 19:10
Analyze the factors that influence the choice between the following pairs of processes to make the products indicated: i) sand casting versus die casting of an electric-motor housing ii) thread rolling versus machining of a bolt for high-strength application. (co3/c5)
Answers: 3
question
Engineering, 04.07.2019 19:20
Apiping systems consists of 6 m of 6-std type k and 12 m of 4-std type k, both drawn copper tubing. the system conveys ethylene glycol at a rate of 0.013 m3/s. the pressure drop across the system is to be calculated. there are two 90° elbows in the 6-in pipe, a reduction from the 6-in pipe to the 4-in pipe and four 90° elbows in the 4-in pipe. all fittings are soldered (same as flanged) and regular. the inlet and outlet of the system are at the same height.
Answers: 1
question
Engineering, 04.07.2019 19:20
Acarnot refrigerator operates in a room in which the temperature is 21°c and of power when operating. if the food compartment of the refrigerator is consumes 3 kw to be maintained at 2°c, determine (a) the coefficient of performance of the cycle and (b) the rate of heat removal from the food compartment. refrigerator cycle that has a higher coefficient of performance than that of the discussed (e) is it possible to develop a carn ot refrigerator, operating between the same temperature limits? explain
Answers: 2
You know the right answer?
Design the flexural reinforcement of a tied column in a reinforced concrete frame is subjected to th...
Questions
question
History, 19.12.2020 14:00
question
Mathematics, 19.12.2020 14:00
question
Chemistry, 19.12.2020 14:00
question
Mathematics, 19.12.2020 14:00
Questions on the website: 13722360