You purchased a computer with the following features: • 95% of all memory accesses are found in the cache.• each cache block is two words, and the whole block is read on any miss.• the processor sends references to its cache at the rate of 109 words per second.• 25% of those references are writes.• assume that the memory system can support 109 words per second, reads or writes.• the bus reads or writes a single word at a time (the memory system cannot read or write two words at once).• assume at any one time, 30% of the blocks in the cache have been modified.• the cache uses write allocate on a write miss.• you are considering adding a peripheral to the system, and you want to know how much of the memory system bandwidth is already used. calculate the percentage of memory system bandwidth used on the average in the two cases below. be sure to state your assumptions. a. case 1: the cache is write through. b. case 2: the cache is write back.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:20
Asimple rankine cycle uses water as the working fluid. the water enters the turbine at 10 mpa and 480c while the condenser operates at 6 kpa. if the turbine has an isentropic efficiency of 80 percent while the pump has an isentropic efficiency of 70 percent determine the thermal efficiency
Answers: 1
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
question
Engineering, 06.07.2019 03:20
What is the maximum height from which a mass of 30 kg can fall on to a flange on the lower end of a vertical rod of length 1.0 m and diameter 20 mm, the upper end being rigidly fixed, if the stress in the rod is not to exceed 80 mpa? the tensile modulus of the rod is 200 gpa.
Answers: 3