You wish to capture particles with a 3 um radius suspended in a fluid that has a linear density gradient with a density of 1.12 g/cm3 at the bottom and 1.00 g/cm at the top. you layer a thin particle suspension on the top of the 6 cm column of fluid with a viscosity of 1.0 cp and allow particles to settle. a) how long must you wait for particles with a density of 1.07 g/cm to sediment to within 0.1 cm of their isopycnic level (i. e., within 0.1 cm of the position where the density of the particles and the density of the fluid are equal)? b) instead of settling due to gravity, you choose to use a centrifuge running at 800 rpm. if the top of the fluid is 5 cm from the center of rotation, how long must you run the centrifuge for the particles to move to within 0.1 cm of their isopycnic level?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
You know the right answer?
You wish to capture particles with a 3 um radius suspended in a fluid that has a linear density grad...
Questions
question
Mathematics, 27.08.2020 06:01
question
Mathematics, 27.08.2020 06:01
question
Mathematics, 27.08.2020 06:01
question
Mathematics, 27.08.2020 06:01
question
Mathematics, 27.08.2020 06:01
question
Mathematics, 27.08.2020 06:01
Questions on the website: 13722367