subject
Engineering, 24.01.2020 05:31 mat1413

In a river reach, the rate of inflow at any time is 350 cfs and the rate of outflow is 285 cfs. after 90 min, the inflow and outflow are 250 cfs and 200 cfs, respectively, and storage of 10.8 acre-ft has been observed. determine the change in storage in 90 min and the initial storage volume.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
Which of the following controllers anticipates the future from the slope of errors over time? a)-proportional b)-on/off c)-integral d)-derivative.
Answers: 2
question
Engineering, 04.07.2019 18:20
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
question
Engineering, 05.07.2019 19:10
Tech a says never use a water hose to clean up dust after a repair. tech b says never use a floor scrubber to clean up dust after repairs. who is correct?
Answers: 1
You know the right answer?
In a river reach, the rate of inflow at any time is 350 cfs and the rate of outflow is 285 cfs. afte...
Questions
question
Mathematics, 28.09.2020 01:01
question
Spanish, 28.09.2020 01:01
question
Mathematics, 28.09.2020 01:01
question
Mathematics, 28.09.2020 01:01
question
Mathematics, 28.09.2020 01:01
question
History, 28.09.2020 01:01
question
Mathematics, 28.09.2020 01:01
Questions on the website: 13722362