An air conditioning unit is to be provided for a restaurant shown in the figure below. the restaurant is situated on the first floor of the building. the floor and ceiling are of 11.25 cm rcc + 11.25 cm lime concrete with 1.25 cm plaster on the inside with mass = 450 kg/m3 oc. the temperature on the ground floor and second floor and adjoining storage kitchen and rest room
is kept 3 oc higher than the room design condition. the following servey data is available at 6pm the peak load time. 15pt outside design condition: 42.7oc dbt, 27.1oc wbt, wo = 16.1 gms/kg inside design condition: 26.7oc dbt, w = 11 gms/kg occupancy at peak load: 100 people seated, 12 employee – medium activity. lights: 6000 watts daily range: 16 oc wall construction: 22.5 cm brick wall + 1.25 cm plaster on both sides, dark color, u = 2.01 w/m2 k, mass = 500 kg/m2 outside temperature at 3 pm = 42.7 oc. fan motor = 2.2 kw. duct heat gain = 4% of internal sensible heat gain. ordinary glass is used with u = 6.02 w/m2 k. inside ventilation blind are used as a shading device. find out the capacity of the plant, and shf for restaurant. location: north (shaded

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 18:10
Water at 70°f and streams enter the mixing chamber at the same mass flow rate, determine the temperature and the quality of the exiting stream. 0 psia is heated in a chamber by mixing it with saturated water vapor at 20 psia. if both streams enters the mixing chamber at the same mass flow rate, determine the temperature and the quality of the existing system.
Answers: 2
question
Engineering, 04.07.2019 18:10
Carbon dioxide gas expands isotherm a turbine from 1 mpa, 500 k at 200 kpa. assuming the ideal gas model and neglecting the kinetic and potential energies, determine the change in entropy, heat transfer and work for each kilogram of co2.
Answers: 2
question
Engineering, 04.07.2019 18:10
Items are similar to the free issue items, but their access is limited. (clo5) a)-bin stock items free issue b)-bin stock controlled issue c)-critical or insurance spares d)-rebuildable spares e)-consumables
Answers: 1
You know the right answer?
An air conditioning unit is to be provided for a restaurant shown in the figure below. the restauran...
Questions
question
Mathematics, 10.04.2020 22:56
Questions on the website: 13722359