subject
Engineering, 06.03.2020 15:57 kaliyab191

In the flow past a compression corner, the upstream Mach number and static pressure are 3.5 and 1 atm, respectively. Downstream of the corner, the pressure is 5.48 atm. Calculate the deflection angle of the corner.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
question
Engineering, 06.07.2019 03:30
Abrayton cycle operates with a regenerator on the air-standard with properties evaluated at 400 k. the tem- perature of the air entering the compressor is 350k while the temperature of the air exiting the compressor is 600 k. the temperature of the air entering the turbine is 1600 k. the overall cycle produced 600 kj/kg of net work out. assuming a regenerator effectiveness of 0.8, what is the temperature of the air before heat addition (combustion)? draw this process on a t - s diagram
Answers: 3
question
Engineering, 06.07.2019 04:10
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the evaporator at 500c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c with a quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, b)-the mass flow rate of the refrigerant . (c) the heating load and the cop of the pump, and d)-the theoretical minimum power input to the compressor for the same heating load.
Answers: 3
You know the right answer?
In the flow past a compression corner, the upstream Mach number and static pressure are 3.5 and 1 at...
Questions
question
English, 28.01.2021 04:40
question
Computers and Technology, 28.01.2021 04:40
question
Physics, 28.01.2021 04:40
question
Mathematics, 28.01.2021 04:40
question
Arts, 28.01.2021 04:40
Questions on the website: 13722361