subject
Engineering, 16.03.2020 17:01 zoriahmendoza

When all conductors of the same alternating-current circuit are in the same raceway, the magnetic flux around each conductor flux of the other circuit conductorsthe magnetic

a. adds to
b. cancels out
C. reverses
d. doubles

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 06.07.2019 03:30
The load on a bolt consists of an axial pull of 10 kn together with a transverse shear force of 5 kn. the bolt material has a yield strength of syt syc 100 mpa. find the diameter of the bolt at factor of safety n-0.5, n 1 and n-2 using maximum shear stress theory
Answers: 3
question
Engineering, 06.07.2019 04:10
Cold water (cp=4180j/kg k) leadıng to a shower enters a thin-walled double-pipe heat transfer at 15c at a rate of 0.25kg/s and is heated to 45c by hot water (cp=4190j/kg k) that enters at 100c at the rate of 3kg/s. if the overall heat transfer coefficient is 950w /m2 k , determıne the rate of heat transfer and the heat transfer surface area of the heat exchanger using e - ntu method
Answers: 1
question
Engineering, 06.07.2019 04:20
Steam in a heating system flows through tubes whose outer radius is 2.5 cm and whose walls are maintained at a temperature of 180 °c . circular aluminum alloy 2024-t6 fins ( k= 186 wm. k) of outer radius 3 cm and constant thickness 1 mm are attached to the tube. the space between the fins is 3 mm and thus there are 250 fins per meter of tube length. heat is transferred to the surrounding air at too-25 °c, with a heat transfer coefficient of 40 w/m2. k. manufacturer a claims that this system is rated at 3.5 kw per meter of tube length. if the fins are an integral part of the steam tube, find the heat transfer rate in kw for a 1-m length of tube. is manufacturer a's claim valid? compare the heat transfer rate from 1 meter of tube length if there are no fins.
Answers: 3
You know the right answer?
When all conductors of the same alternating-current circuit are in the same raceway, the magnetic fl...
Questions
question
Mathematics, 21.07.2021 09:20
question
Mathematics, 21.07.2021 09:20
question
Mathematics, 21.07.2021 09:20
question
Computers and Technology, 21.07.2021 09:20
question
Computers and Technology, 21.07.2021 09:30
Questions on the website: 13722367