The data below were obtained for the adsorption of CO on charcoal at 273 K using an instrument that measures the volume (corrected to 1 atm pressure) of gas molecules that become adsorbed onto a surface as a function of its pressure in the surround gas phase. Such measurements are commonly performed in order to quantify the surface area of a material. The charcoal sample had a mass of 0.5 g and a CO adsorption site density of 5x10¹⁵ cm⁻².

Pco (torr) 100 200 300 400 500 600 700
V (cm³) 10.3 19.3 27.3 34.1 40 45.5 48

(a) Is the data consistent with a Langmuir isotherm? Support your answer. Hint: you will need to modify the Langmuir isotherm for a single species to convert θ_a to V.
(b) Determine the adsorption equilibrium ratio (Kco) and the volume of CO that is adsorbed at complete coverage.
(c) What is the total surface area (S_a) of the piece of charcoal in m² per gram of charcoal?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 03.07.2019 23:20
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Afluid flows with a velocity field given by v=(x/t)i.. determine the local and convective accelerations when x=3 and t=1.
Answers: 2
You know the right answer?
The data below were obtained for the adsorption of CO on charcoal at 273 K using an instrument that...
Questions
question
Computers and Technology, 06.10.2021 15:20
question
Mathematics, 06.10.2021 15:20
question
Mathematics, 06.10.2021 15:20
question
Chemistry, 06.10.2021 15:20
question
Physics, 06.10.2021 15:20
question
Mathematics, 06.10.2021 15:20
Questions on the website: 13722367