subject
Engineering, 24.03.2020 00:27 xbeatdroperzx

What is the second con sideration when determining footing depth?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
question
Engineering, 06.07.2019 05:10
Draw each component in sequence for a steam (rankine cycle) power plant. draw the system boundary needed to analyze this cycle as a closed system. note: this should just be one figure below! else
Answers: 2
question
Engineering, 06.07.2019 05:10
Determine the heat loss per hour from a wall of a build- ing when the wind is blowing parallel to its surface with a speed of 2 km/hour. the wall is 5 metre long and 3 metre high. tempe rature of the wall is 25°c and air temperature is 5°c.
Answers: 2
question
Engineering, 06.07.2019 05:20
A8-in.-diameter steel shaft is to have a press fit with a 16-in-diameter cast iron hub. both the hub and the shaft are 10 in long. using maximum normal stress theorem and appropriate safety factor, it was identified that the maximum allowable circumferential (a.k.a. hoop or tangential) stress in the hub is to be 7.5 ksi. the moduli of elasticity are 30 x 106 psi for steel and 15 x 106 psi for cast iron. the poisson's ratio for both steel and cast ron is 0.3 and coefficient friction for the two materials is 0.12. determine a. the interference or the original mismatch, 8 b. the maximum axial force required to press the hub on the shaft
Answers: 1
You know the right answer?
What is the second con sideration when determining footing depth?...
Questions
question
Mathematics, 13.10.2020 01:01
question
Mathematics, 13.10.2020 01:01
question
Mathematics, 13.10.2020 01:01
question
Mathematics, 13.10.2020 01:01
question
Mathematics, 13.10.2020 01:01
question
Mathematics, 13.10.2020 01:01
question
Computers and Technology, 13.10.2020 01:01
Questions on the website: 13722362