subject
Engineering, 24.03.2020 04:58 myaa114

1. Assume that EAX contains ff ff ff 51 and the doubleword referenced by value contains ff ff ff f1.

a. True
b. False.

2. The conditional jump statement add eax, value js dest causes a jump to the label dest.

a. True
b. False

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
question
Engineering, 06.07.2019 02:30
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
question
Engineering, 06.07.2019 04:10
An inventor claims to have developed a reversed heat engine (ie. a heat pump) which is able to deliver 10 kj heat into the room at 20°c from outside ambient temperature of -10°c by consuming only 2 kj electricity in winter. this claim is a)-impossible b)-possible only if the heat pump is ideal c)-practically possible d)-unable to be assessed as it depends on the working fluid used in the heat pump.
Answers: 2
You know the right answer?
1. Assume that EAX contains ff ff ff 51 and the doubleword referenced by value contains ff ff ff f1....
Questions
question
Computers and Technology, 03.11.2020 16:00
question
Mathematics, 03.11.2020 16:00
question
Chemistry, 03.11.2020 16:10
question
Mathematics, 03.11.2020 16:10
question
History, 03.11.2020 16:10
Questions on the website: 13722362