subject
Engineering, 25.03.2020 21:47 merrickrittany

Polymer implants have been used for the controlled release of drugs and genes in biological tissues. Consider a polymer membrane implanted in a tissue. To simplify the analysis of controlled drug release, we assume that the tissue is much larger than the thickness of the implant. In addition, we assume that the clearance of a drug in the tissue is very slow, so that the concentration of the drug at the tissue-implant interface is equal to the solubility C0 of the drug. Also, the transport of drug in the tissue is one dimensional and in the normal direction of the membrane. Finally, we assume that convection and drug clearance through blood and lymph vessels are negligible. Thus, drug transport in the tissues involves only diffusion. Given the following, calculate the effective diffusion coefficient with respect to the drug’s known diffusion coefficient in plasma (61 µm2 /s).

If the effective diffusion coefficient is Deff and there is no drug in the tissue initially, what is the concentration of the drug 50µm away the implant 24 hours after implantation?

Known: Ratio of the pore surface area to the polymer surface area = 0.01, the drug radius of gyration is 3 nm, the pore radius is 8 nm, the polymer thickness is 10 microns and the tortuosity is 1.5.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 19:10
Analyze the factors that influence the choice between the following pairs of processes to make the products indicated: i) sand casting versus die casting of an electric-motor housing ii) thread rolling versus machining of a bolt for high-strength application. (co3/c5)
Answers: 3
question
Engineering, 04.07.2019 19:20
Apure substance is a)-mixture of various chemical elements or compounds b)-substance that has a fixed chemical composition throughout c)-mixture that is homogeneous (such as air) d)-all the answers
Answers: 3
question
Engineering, 04.07.2019 19:20
The quality is zero at a)-the saturated vapour state b)-the saturated liquid state c)-the saturated liquid-vapour mixture state d)-none of the states in the other answers
Answers: 3
question
Engineering, 04.07.2019 19:20
Apiping systems consists of 6 m of 6-std type k and 12 m of 4-std type k, both drawn copper tubing. the system conveys ethylene glycol at a rate of 0.013 m3/s. the pressure drop across the system is to be calculated. there are two 90° elbows in the 6-in pipe, a reduction from the 6-in pipe to the 4-in pipe and four 90° elbows in the 4-in pipe. all fittings are soldered (same as flanged) and regular. the inlet and outlet of the system are at the same height.
Answers: 1
You know the right answer?
Polymer implants have been used for the controlled release of drugs and genes in biological tissues....
Questions
question
Biology, 02.04.2022 14:00
Questions on the website: 13722359