Design a lead compensator for the closed-loop (CL) system whose open loop transfer function is given below. Design objectives: reduce the time constant by 50% while increase the damping ratio to sqrt(3)/2 for the dominant poles. Please note that H(s)=1. Please use the method based on root locus plot.

G(s)=2 / [s(s+2)]

Please include detailed step.

Obtain the location of the desired dominant poles.
Draw the root loci of the CL system without the lead compensator
Calculate the angle deficiency.
Determine the location of the pole associated with the lead compensator if the zero is chosen to be at (-2.5, 0)
Obtain the gain value of the compensator (Hint: use the Magnitude Condition)
Write the complete expression of the lead compensator.
The following requires the use of Matlab (please write a Matlab script file):

Upon finishing the design, please use Matlab to plot the root loci of CL systems with and without the lead compensator. Mark the locations of the desired dominant poles. Please make sure that the root loci of CL systems with the lead compensator pass through the desired dominant poles.
Simulate and compare the unit step responses of the uncompensated and compensated system. Please observe from the plots and comment if the design objectives have been achieved.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
Determine the damped natural frequencies and the steady state response of a decoupled damped forced two degrees of freedom system. 10ä1 + 2q1 20q1 10 cos t; 10q2 +4q2 + 40q2 10 cos t
Answers: 3
You know the right answer?
Design a lead compensator for the closed-loop (CL) system whose open loop transfer function is given...
Questions
question
Chemistry, 09.10.2019 22:30
Questions on the website: 13722363