Engineering, 07.04.2020 19:34 curtez11

Consider a rack system with a storage rack of dimensions (inches) of 56m (length) by 58n (height), where m is the number of horizontal addresses and n is the number of ver>cal addresses. Assume m = 80, n = 12, and that the S/R requires 0.35 min to perform a P/D opera>on, travels horizontally at an average speed of 350 fpm, and travels ver>cally at an average speed of 60 fpm.

Suppose that 40% of storage and retrieval opera>ons are performed as single command and the remaining are performed as dual command. Assume that there are 120 storages per hr and 120 retrievals per hr and that there are 8 S/R machines that are loaded uniformly.

(i) What is the percent utulization of the S/R machines?

(ii) What is the average cycle time per operation (storage/retrieval)?

(iii) What is the maximum throughput (operations per hour) of this AS/R system?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Carbon dioxide gas expands isotherm a turbine from 1 mpa, 500 k at 200 kpa. assuming the ideal gas model and neglecting the kinetic and potential energies, determine the change in entropy, heat transfer and work for each kilogram of co2.
Answers: 2
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
question
Engineering, 04.07.2019 18:20
For a gate width of 2 m into the paper, determine the force required to hold the gate abc at its location.
Answers: 1
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
Consider a rack system with a storage rack of dimensions (inches) of 56m (length) by 58n (height), w...