subject
Engineering, 08.04.2020 00:11 KRLoopy4722

A CMFR will be used to reduce the concentration of chloroform(CHCl3) in water. Chloroform is a disinfection by-product that is formed when chlorine is used to disinfect water; it is a concern because it can cause cancer. The influent water contains 60 ppb chloroform and the Wisconsin State standard is 6 ppb. Chloroform decays in the reactor at a rate of 0.2 hr-1 and the water flow rate is 100 L/day.

Treating the water to meet the Wisconsin standard will reduce the lifetime cancer risk for ingesting the water to 10-5.Although this is within the range of the EPA risk guidelines (10-4to 10-7), the public is concerned about the presence of a carcinogenic compound in their water. Determine the size (in L) of the reactor necessary to achieve (a)a risk of 10-5(6 ppb) and (b)a risk of 10-7(0.06 ppb).How do the two reactors compare? Do you think it will be worth the extra cost to reduce the risk from 10-5to 10-7?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 19:20
Acircular pipe of 30mm outside diameter is placed in an airstream at 30 c and latm pressure. the air moves in cross flow over the pipe at 20 m/s, while the outer surface of the pipe is maintained at 110 c. what is the drag force exerted on the pipe per unit length? what is the rate of heat transfer from the pipe per unit length?
Answers: 1
question
Engineering, 04.07.2019 19:20
Apreheater involves the use of condensing steam at 100°c on the inside of a bank of tubes to heat air that enters at 1 atm and 25°c. the air moves at 5 m/s in cross flow over the tubes. each tube is 1 m long and has an outside diameter of 10 mm. what is the minimum value of nl needed to achieve an outlet temperature of t 75 c? what is the corresponding pressure drop across the tube bank?
Answers: 3
You know the right answer?
A CMFR will be used to reduce the concentration of chloroform(CHCl3) in water. Chloroform is a disin...
Questions
Questions on the website: 13722360