subject
Engineering, 16.04.2020 01:26 lucarignot

A heating system must maintain the interior of a building at TH = 20°C when the outside temperature is TC = 10°C. If the rate of heat transfer from the building through its walls and roof is 15 kW, determine the electrical power required, in kW, to heat the building using: (a) electrical-resistance heating; (b) a heat pump whose coefficient of performance is 4; (c) a reversible heat pump operating between hot and cold reservoirs at 20°C and 10°C, respectively.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 19:10
The short distance from the objective lens to the object causes problems at high magnification. which of the following is the most serious? a. cleaning the object surface b. positioning the object c. reflection from the object surface. d. illumination of the object
Answers: 1
question
Engineering, 04.07.2019 19:20
Acarnot refrigerator operates in a room in which the temperature is 21°c and of power when operating. if the food compartment of the refrigerator is consumes 3 kw to be maintained at 2°c, determine (a) the coefficient of performance of the cycle and (b) the rate of heat removal from the food compartment. refrigerator cycle that has a higher coefficient of performance than that of the discussed (e) is it possible to develop a carn ot refrigerator, operating between the same temperature limits? explain
Answers: 2
question
Engineering, 06.07.2019 02:30
Precipitation hardening can be achieved in many light alloys by a three-step heat treatment. what is carried out and what is the purpose at each step? why is such a treatment necessary based on the nucleation and growth theory of phase transformation. compare this treatment with tempering martensite for carbon steels (similarities and differences).
Answers: 1
You know the right answer?
A heating system must maintain the interior of a building at TH = 20°C when the outside temperature...
Questions
question
Mathematics, 10.09.2021 18:10
question
Social Studies, 10.09.2021 18:10
question
Mathematics, 10.09.2021 18:10
question
History, 10.09.2021 18:10
Questions on the website: 13722359