subject
Engineering, 17.04.2020 03:53 sagetpc68741

G A composite beam is built of a wood member having cross-sectional dimensions 150mm x 250mm and two steel plates of cross-sectional dimensions 50mm x 150mm. Determine the maximum stress in the steel and the maximum stress in the wood if the beam is subjected to a bending moment M of 100 kN-m. The moduli of elasticity for the wood are steel are Ew

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
question
Engineering, 06.07.2019 04:10
Cold water (cp=4180j/kg k) leadıng to a shower enters a thin-walled double-pipe heat transfer at 15c at a rate of 0.25kg/s and is heated to 45c by hot water (cp=4190j/kg k) that enters at 100c at the rate of 3kg/s. if the overall heat transfer coefficient is 950w /m2 k , determıne the rate of heat transfer and the heat transfer surface area of the heat exchanger using e - ntu method
Answers: 1
question
Engineering, 06.07.2019 04:30
At steady state, air enters an insulated duct of varying cross-sectional area (similar to a nozzle or diffuser) at 200 kpa, 52°c with a mass flow rate of 0.5 kg/s. at the duct exit, the pressure of the air is 100 kpa, the velocity is 255 m/s, and the cross-sectional area is 2 x 10-3 m^2. assuming an ideal gas model, determine: a)-find the specific volume of the air at the exit, in m3/kg. b)- the temperature of the air at the exit, in k. c)-the velocity of the air at the inlet, in m/s. d)-the inlet cross-sectional area, in m^2.
Answers: 1
question
Engineering, 06.07.2019 05:10
Air undergoes a constant pressure cooling process with no moisture added or removed. the air originally exists at 45 °c, 150 kpa and 35 % relative humidity. it is cooled until the temperature reaches 29 oc. determine (a) the relative humidity of the cooled air. (b) the dew point temperature of the cooled air in °c. (c) the heat removed during the cooling process in kj/kg. use the psychrometric chart to check your answers (this part will not be graded; however, it will you get comfortable using the psychrometric chart)
Answers: 3
You know the right answer?
G A composite beam is built of a wood member having cross-sectional dimensions 150mm x 250mm and two...
Questions
question
Mathematics, 20.09.2020 09:01
Questions on the website: 13722363