Engineering, 20.04.2020 10:23 larageorge

The customer is not greatly concerned with an inefficient power factor, provided that sufficient

power reaches the load. To make the customer more aware of power factor considerations, the

power company may install a penalty on the customer’s bill. A typical penalty power factor chart

is shown in Table 1. Power factors below 0.6 are not permitted, if a customer records power

factor below 0.6 a 25 percent penalty is applied.

Table 1. Penalty for low power factor

Power factor Penalty

0.9 and higher none

0.8 to 0.899 1%

0.7 to 0.799 2%

0.6 to 0.699 3%

An industrial plant you work for connects four loads in parallel to a 400V, 50 Hz supply.

Load 1 absorbs 50 kVar at 0.7 lagging, load 2 absorbs 15 kW and generates 5 kVar, and

load 3 absorbs 5 kW at unity power factor, load 4 has an impedance of 20∠55°.

a) Calculate the branch currents and draw the phasor diagram

b) What % penalty does the company risk facing on its next bill?

c) As an electrical engineer in charge of power factor correction, with a p. f target of unity,

recommend the rating of element or equipment in kVar to use so as to avoid penalties.

- provide the branch currents and the phasor diagrams

- draw the power triangles before and after power factor correction.

d) Verify your answers using Matlab/Simulink

- show the rms currents on the Simulink model

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aflywheel accelerates for 5 seconds at 2 rad/s2 from a speed of 20 rpm. determine the total number of revolutions of the flywheel during the period of its acceleration. a.5.65 b.8.43 c. 723 d.6.86
Answers: 2
question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:10
Compute the pressure drop of 30°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
question
Engineering, 04.07.2019 18:20
Determine the damped natural frequencies and the steady state response of a decoupled damped forced two degrees of freedom system. 10ä1 + 2q1 20q1 10 cos t; 10q2 +4q2 + 40q2 10 cos t
Answers: 3
You know the right answer?
The customer is not greatly concerned with an inefficient power factor, provided that sufficient
Questions
question
Mathematics, 22.04.2020 21:57
question
Mathematics, 22.04.2020 21:57
question
Mathematics, 22.04.2020 21:57
question
Mathematics, 22.04.2020 21:57
Questions on the website: 13722360