subject
Engineering, 21.04.2020 04:24 katieleeisaacs8976

Evaporation in Double-Effect Reverse-Feed Evaporators. A feed containing 2 wt % dissolved organic solids in water is fed to a double-effect evaporator with reverse feed. The feed enters at 100°F and is concentrated to 25% solids. The boiling-point rise can be considered negligible as well as the heat of solution. Each evaporator has a 1000-ft2 surface area and the heat-transfer 700 btu/h -ft2-°F. The feed enters evaporator number 2 and steam at 100 psia is fed to number 1. The pressure iin the vapor space of evaporator number 2 is 0.98 psia. Assume that the heat capacity of all liquid solutions is that of liquid water. Calculate the feed rate F and the product rate Li of a solution containing 25% solids. (Hint: Assume a feed rate of, say, F 1000 lbm/h. Calculate the area. Then calculate the actual coefficients are U1 500 and U2- feed rate by multiplying 1000 by 1000/calculated area.) Ans. F- 133 800 lbm/h (60 691 kg/h), L,- 10700lb»/h (4853 kg/h)

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 19:20
Consider airflow over a flat plate of length l = 1.5 m under conditions for which transition occurs at le = 0.9 m based on the critical reynolds number, re,e = 5 x 10. evaluating the thermophysical properties of air at 400 k, determine the air velocity. (hint: use the tables to find the properties of air)
Answers: 3
You know the right answer?
Evaporation in Double-Effect Reverse-Feed Evaporators. A feed containing 2 wt % dissolved organic so...
Questions
question
History, 15.11.2019 15:31
question
Spanish, 15.11.2019 15:31
question
Mathematics, 15.11.2019 15:31
question
Mathematics, 15.11.2019 15:31
Questions on the website: 13722363