subject
Engineering, 21.04.2020 16:29 collinpeterson21

Water at 300 K overflows the inside of a vertical open pipe of diameter 1m and forms a smooth film of thickness 0.08cm. Pure carbon dioxide at 1atm pressure flows slowly through the inside of the pipe. If the pipe is 3.5m long, and the water enters free of carbon dioxide. (1) At what rate (moles/hr) can carbon dioxide be removed from the system in the existing water stream? (2) Is it a practical device? Explain and suggest improvement or alternative. The Henry’s constant for CO2/water is H=500 atm, where p(atm)=H x CO2, where xCO2 is the mole fraction of CO2 in the solution. The diffusion coefficient of CO2 in water at 300 K is 3x10-6 cm2/s.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The filament of an incandescent lamp has a temperature of 2000k. calculate the fraction of radiation emitted in the visible light band if the filament is approximated as blackbody
Answers: 2
question
Engineering, 04.07.2019 18:20
Modern high speed trains do not have perpendicular expansion gaps where rails are joined end-to-end any more they are mostly welded together but what might happen if there was a spell of particularly hot weather that causes inspection of the tracks?
Answers: 1
question
Engineering, 04.07.2019 19:20
At steady state, air at 200 kpa, 325 k, and mass flow rate of 0.5 kg/s enters an insulated duct having differing inlet and exit cross-sectional areas. the inlet cross-sectional area is 6 cm2. at the duct exit, the pressure of the air is 100 kpa and the velocity is 250 m/s. neglecting potential energy effects and modeling air as an 1.008 kj/kg k, determine ideal gas with constant cp = (a) the velocity of the air at the inlet, in m/s. (b) the temperature of the air at the exit, in k. (c) the exit cross-sectional area, in cm2
Answers: 2
question
Engineering, 04.07.2019 19:20
Aseries piping system conveys methyl alcohol. the system consists of 70 m of 1- nominal pipe follow by 50 m of 2-nominal pipe, both schedule 40 commercial steel. the 1-nominal pipe contains 3 90° elbows (regular) anda fully open gate valve, all threaded. the pressure drop through the system is 150 kpa. determine the volume flow rate through the system that is horizontally laid.
Answers: 1
You know the right answer?
Water at 300 K overflows the inside of a vertical open pipe of diameter 1m and forms a smooth film o...
Questions
question
Mathematics, 04.10.2020 05:01
question
World Languages, 04.10.2020 05:01
question
Mathematics, 04.10.2020 05:01
question
English, 04.10.2020 05:01
question
Mathematics, 04.10.2020 05:01
Questions on the website: 13722367