subject
Engineering, 21.04.2020 20:27 kayranicole1

Estimate the service flow rate for level of service D for a six-lane freeway (three lanes in each direction with 12-ft (3.6m) lanes and obstructions 6 ft (1.8 m) from the edge of pavement. The section is to accommodate 5 percent single unit trucks and 5 percent tractor trailer trucks. The design speed is 75 mph, and the section has a +3 percent grade that is 0.7 mile long. NOTE: assume the road is located in a rural region (i. e. TRD = 0.5 ramps / 1 mile).

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Consider a large isothermal enclosure that is maintained at a uniform temperature of 2000 k. calculate the emissive power of the radiation that emerges from a small aperture on the enclosure surface. what is the wavelength ? , below which 10% of the emission is concentrated? what is the wavelength ? 2 above which 10% of the emission is concentrated? determine the wavelength at which maximum spectral emissive power occurs. what is the irradiation incident on a small object placed inside the enclosure?
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
question
Engineering, 04.07.2019 18:20
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg
Answers: 2
You know the right answer?
Estimate the service flow rate for level of service D for a six-lane freeway (three lanes in each di...
Questions
question
Social Studies, 16.10.2020 09:01
question
Engineering, 16.10.2020 09:01
question
Mathematics, 16.10.2020 09:01
question
Health, 16.10.2020 09:01
question
Mathematics, 16.10.2020 09:01
Questions on the website: 13722367