Engineering, 23.04.2020 20:30 tsigler6425

A steel sphere, at 300°C, holds water at 100 kPa, 300°C. The system (steel plus water) cools to the ambient temperature of 20°C by losing 1988 kJ of heat. During this process the entropy of the steal sphere and water decrease by 3.3 kJ/K and 1.4 kJ/K, respectively. The entropy generation (kJ/K) for this process is most closely equal to:

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Ajournal bearing has a journal diameter of 3.250 in with a unilateral tolerance of 20.003 in. the bushing bore has a diameter of 3.256 in and a unilateral tolerance of 0.004 in. the bushing is 2.8 in long and supports a 700-lbf load. the journal speed is 900 rev/min. find the minimum oil film thickness and the maximum film pressure for both sae 20 and sae 20w-30 lubricants, for the tightest assembly if the operating film temperature is 160°f. a computer code is appropriate for solving this problem.
Answers: 3
question
Engineering, 04.07.2019 18:10
Which of the following controllers anticipates the future from the slope of errors over time? a)-proportional b)-on/off c)-integral d)-derivative.
Answers: 2
question
Engineering, 04.07.2019 19:10
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg.m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 3
question
Engineering, 04.07.2019 19:10
Ahelical coil spring has a mean diameter of 50 mm, a wire diameter of 5.5 mm and is wound with a pitch of 10 mm. the spring steel has an ultimate strength of 1250 mpa. find the force needed to compress the spring solid and the wire stress in this condition. state whether the spring will return to its initial length.
Answers: 1
You know the right answer?
A steel sphere, at 300°C, holds water at 100 kPa, 300°C. The system (steel plus water) cools to the...
Questions
question
French, 05.11.2020 07:10
question
English, 05.11.2020 07:10
question
Social Studies, 05.11.2020 07:10
question
Chemistry, 05.11.2020 07:10
question
Mathematics, 05.11.2020 07:10
Questions on the website: 13722362