Twenty degree C air enters a tube bank which is to be used to remove 150 [kW] of heat from condensing refrigerant. The refrigerant is flowing inside the tubes of the bank and causes the external tube surfaces to be maintained at 100o C. The air is accelerated by a fan to 8 [m/s] upstream of the bank. The bank is to be constructed of transverse rows of fifty 8 [mm] O. D. tubes 0.75 [m] wide with the center-to-center transverse spacing equal to 15 [mm].

Calculate the exit temperature of the air from the bank

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
You know the right answer?
Twenty degree C air enters a tube bank which is to be used to remove 150 [kW] of heat from condensin...
Questions
question
Mathematics, 11.12.2020 06:00
question
Chemistry, 11.12.2020 06:00
question
Mathematics, 11.12.2020 06:00
question
Mathematics, 11.12.2020 06:00
question
Social Studies, 11.12.2020 06:00
question
Chemistry, 11.12.2020 06:00
Questions on the website: 13722360