subject
Engineering, 25.04.2020 04:05 hanjonez

Question 5 (20 pts) The rated current of a three-phase transmission line is 300 A. The currents flowing by the line are measured with three current transformers each with ratio 250 : 5. What is the current you would measure at the secondary of each current transformer if rated current is flowing through each line. (of course the secondaries of the transformer must be part of closed circuits.) Consider the measured currents are exciting three over-current relays. Should the contacts of the relay close if rated current is circulating in the lines? If your answer is between no and yes, the current that the relay observes when rated current flows by the line must be the minimum pick-up current Ip. Hence, the tap position you should select, e. g., in the tap block of Fig. 1, must be equal o slightly greater than Ip for an over-current relay. Slightly greater when Ip is not an integer that matches the tap selection.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 18:10
Draw the engineering stress-strain curve for (a) bcc; (b) fcc metals and mark important points.
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
Question 5 (20 pts) The rated current of a three-phase transmission line is 300 A. The currents flow...
Questions
question
Mathematics, 08.12.2020 23:00
question
Mathematics, 08.12.2020 23:00
question
Mathematics, 08.12.2020 23:00
question
Mathematics, 08.12.2020 23:00
question
Mathematics, 08.12.2020 23:00
Questions on the website: 13722367