subject
Engineering, 21.05.2020 00:11 BreBreDoeCCx

A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at 2358C by rejecting waste heat to cooling water that enters the condenser at 188C at a rate of 0.25 kg/s and leaves at 268C. The refrigerant enters the condenser at 1.2 MPa and 508C and leaves at the same pressure subcooled by 58C. If the compressor consumes 3.3 kW of power, determine (a) the mass flow rate of the refrigerant, (b) the refrigeration load, (c) the COP, and (d) the minimum power input to the compressor for the same refrigeration load.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 04.07.2019 18:10
Ariver flows from north to south at 8 km/h. a boat is to cross this river from west to east at a speed of 20 km/h (speed of the boat with respect to the earth/ground). at what angle (in degrees) must the boat be pointed upstream such that it will proceed directly across the river (hint: find the speed of the boat with respect to water/river)? a 288 b. 21.8 c. 326 d. 30.2
Answers: 3
question
Engineering, 06.07.2019 03:20
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2
question
Engineering, 06.07.2019 04:10
Aheat pump that operates on the ideal vapor compression cycle with refrigerant-134a is used to heat water from 15°c to 45°c at a rate of 0.12 kg/s. the condenser and evaporator pressures are 1.4 and 0.32 mpa, respectively determine: (a) the power input to the heat pump
Answers: 1
You know the right answer?
A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerate...
Questions
question
Mathematics, 01.12.2020 20:20
question
Business, 01.12.2020 20:20
question
Mathematics, 01.12.2020 20:20
question
Mathematics, 01.12.2020 20:20
Questions on the website: 13722367