A double-pipe heat exchanger is used to cool a hot fluid (cp = 3800 J/kg·K) entering the heat exchanger at 200°C with a flow rate of 0.4 kg/s. In the cold side, cooling fluid (cp = 4200 J/kg·K) enters the heat exchanger at 10°C with a mass flow rate of 0.5 kg/s. The double-pipe heat exchanger has a thin-walled inner tube, with convection heat transfer coefficients inside and outside of the inner tube estimated to be 1400 W/m2 ·K and 1100 W/m2 ·K, respectively. The heat exchanger has a heat transfer surface area of 2.5 m2 , and the estimated fouling factor caused by the accumulation of deposit on the surfaces is 0.0002 m2 ·K/W. (a) Determine the effectiveness values for the parallel- and counter-flow configurations. (b) Determine outlet temperatures of the hot fluid for the parallel- and counter-flow configurations. (c) Determine outlet temperatures of the cold fluid for the parallel- and counter-flow configurations.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Burgers vector is generally parallel to the dislocation line. a)-true b)-false
Answers: 2
question
Engineering, 04.07.2019 18:10
Slip occurs via two partial dislocations because of (a) the shorter path of the partial dislocation lines; (b) the lower energy state through partial dislocations; (c) the charge balance.
Answers: 1
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
question
Engineering, 04.07.2019 19:10
Air inially occupying a volume of 1 m2 at 100 kpa, 27 c undergoes three internally reversible processes in series. process 1-2 compression to 500 kpa during which pv constant process 2-3 adiabatic expanslon to 100 kpa process 3-1: constant-pressure expansion to 100 kpa (a) calculate the change of entropy for each of the three processes. (b) calculate the heat and work involved in each process. (c) is this cycle a power cycle or refrigeration cycle?
Answers: 3
You know the right answer?
A double-pipe heat exchanger is used to cool a hot fluid (cp = 3800 J/kg·K) entering the heat exchan...
Questions
question
Biology, 06.07.2021 21:40
Questions on the website: 13722360