subject
Engineering, 28.05.2020 01:00 sha712

When the fuel pedal is partially repressed up shift occurs sooner and at a engine speed

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 06.07.2019 02:30
Air (c-1.006 kj/kg.k, r-0.287 kj/kg.k) enters a nozzle steadily at 280 kpa and 77°c with a velocity of 50 m/s and exits at 85 kpa and 320 m/s. the heat losses from the nozzle to the surrounding medium at 20°c are estimated to be 3.2 kj/kg. determine (a) the exit temperature and (b) the total entropy change for this process. solve this problem using constant specific heats.
Answers: 1
question
Engineering, 06.07.2019 04:10
Aspherical thermocouple measurement errors a spherical thermocouple made of constantin transfer coefficient between the gas and the thermocouple is h used to measure the temperature of a gas. the heat 400 w/m2 k. calculate the maximum diameter d of the thermocouple if the thermocouple's measurement error should be w 23 within 5% of the initial temperature difference in 5 seconds. for constantin, k 8920 kg/m3, and c 410 j/kg. k.
Answers: 3
question
Engineering, 06.07.2019 04:20
Steam in a heating system flows through tubes whose outer radius is 2.5 cm and whose walls are maintained at a temperature of 180 °c . circular aluminum alloy 2024-t6 fins ( k= 186 wm. k) of outer radius 3 cm and constant thickness 1 mm are attached to the tube. the space between the fins is 3 mm and thus there are 250 fins per meter of tube length. heat is transferred to the surrounding air at too-25 °c, with a heat transfer coefficient of 40 w/m2. k. manufacturer a claims that this system is rated at 3.5 kw per meter of tube length. if the fins are an integral part of the steam tube, find the heat transfer rate in kw for a 1-m length of tube. is manufacturer a's claim valid? compare the heat transfer rate from 1 meter of tube length if there are no fins.
Answers: 3
You know the right answer?
When the fuel pedal is partially repressed up shift occurs sooner and at a engine speed...
Questions
question
English, 27.09.2021 09:30
question
Mathematics, 27.09.2021 09:30
question
Mathematics, 27.09.2021 09:30
question
Mathematics, 27.09.2021 09:30
question
Geography, 27.09.2021 09:30
Questions on the website: 13722362