The viscosity of liquids can be measured through the use of rotating-cylinder viscosimeter of
...
Engineering, 02.06.2020 23:58 Geo777
The viscosity of liquids can be measured through the use of rotating-cylinder viscosimeter of
the type shown in Figure 2. In this device, the outer cylinder is fixed and the inner cylinder
is rotated with an angular frequency, ω. The torque, T, required to maintain a constant
ω is measured and the dynamic viscosity, µ, is calculated from these two measurements.
By neglecting end effects and assuming the velocity distribution in the gap to be linear, an
equation relating µ, ω, T, l, R0, and Ri may be written as
2πRi
3lω T = µ. R0 − Ri
a) Derive this equation and show that it is dimensionally correct.
The following torque-angular velocity data were obtained with a rotating-cylinder viscosimeter with R0 = 6.0 cm, Ri = 5.9 cm, and l = 25.0 cm:
Torque (N m· ) 0.178 0.353 0.536 0.715 0.880 1.066
Angular velocity 1.0 2.0 3.0 4.0 5.0 6.0
(rad/s)
b) Give your best estimate of the viscosity, µ.
c) Indicate the accuracy of this estimate.
d) Using Appendix B in Young et al.’s book, what fluid do you think was used if the temperature of the fluid was 15oC.
Answers: 1
Engineering, 04.07.2019 18:20
Acertain flow of air (at stp) has a velocity distribution given by v i (in ft/s). if this flow is going through a 4 ft square area in the yz-plane (centered at the origin), what is the mass flow rate (in lbm/s)?
Answers: 2
Engineering, 04.07.2019 19:20
Apiping systems consists of 6 m of 6-std type k and 12 m of 4-std type k, both drawn copper tubing. the system conveys ethylene glycol at a rate of 0.013 m3/s. the pressure drop across the system is to be calculated. there are two 90° elbows in the 6-in pipe, a reduction from the 6-in pipe to the 4-in pipe and four 90° elbows in the 4-in pipe. all fittings are soldered (same as flanged) and regular. the inlet and outlet of the system are at the same height.
Answers: 1
Engineering, 06.07.2019 02:30
Precipitation hardening can be achieved in many light alloys by a three-step heat treatment. what is carried out and what is the purpose at each step? why is such a treatment necessary based on the nucleation and growth theory of phase transformation. compare this treatment with tempering martensite for carbon steels (similarities and differences).
Answers: 1
Engineering, 06.07.2019 05:10
An ideal vapor-compression refrigeration cycle is employed to maintain a building temperature of 23°c when the outside temperature is 37°c. the cycle operates at steady state using ammonia as the working fluid. the mass flow rate of the refrigerant is 15 kg/min. the refrigerant enters the compressor at 1.5 bar and 10 °c. the condenser pressure is 20 bar and the temperature at the condenser exit is 45 °c. determine (a) the compressor power in kw. (b) the refrigeration capacity in tons. (c) the coefficient of performance. d) the maximum theoretical coefficient of performance.
Answers: 2