subject
Engineering, 07.07.2020 16:01 mariahernandez237503

A wood pole with a diameter of 10 in. has a moisture content of 5%. The fiber saturation point (FSP) for this wood is 30%. The wood shrinks or swells 1% (relative to the green dimensions) in the radial direction for every 5% change in moisture content below FSP. a. What would be the percent change in the wood's diameter if the wood's moisture is increased to 55%? b. Would the wood swell or shrink? c. What would be the new diameter?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 19:10
The air in an automobile tire with a volume of 0.015 m3 is at 32°c and 140 kpa gage. determine the amount of air that must be added to raise the pressure to the recommended value of 206 kpa gage. assume the atmospheric pressure to be 128 kpa and the temperature and the volume to remain constant.[r-0.287 kj/kgk]
Answers: 3
question
Engineering, 06.07.2019 02:30
A75mm diameter shaft is supported in a journal bearing 75mm long with a diametral clearance of 0. 1mm. it supports a radial load of 1000 n and is lubricated with sae 50 oil at 70°c. find the friction torque and the power loss when the crankshaft rotates at 2900 rev/min.
Answers: 1
question
Engineering, 06.07.2019 02:30
1in2 processor chip can be modelled as an isothermal plane wall of silicon, isothermal on both sides. the power input to the bottom of the plane wall, or the processing power of the chip, often called the thermal design power (tdp), is 100w. assume the periphery is adiabatic. the silicon is 400 microns thick. the temperature at the junction, or in this case on the bottom of the isothermal plane wall, is 85°c. what is the top surface temperature, assuming that the only mode of heat transfer is conduction
Answers: 1
question
Engineering, 06.07.2019 03:20
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2