subject
Engineering, 04.08.2020 17:01 lolweapon

A temperature measurement system was used to measure the temperature of gases exiting a heating unit. The measurement system has the characteristics shown in the table below. The data from 10 measurements are shown in the other table below. Using these data, calculate the 95% uncertainty interval for the mean temperature of the population. Linearity ± 1 K over range Hysteresis ± 1 K over range Repeatability ± 2 K over range Resolution ± 0.5 K over range Digitization 16 bits Range 800 K to 1500 KExperimental Data:i Ti(K)1 11082 10733 10954 10855 11096 11047 11238 10789 107510 1095

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:20
Determine the damped natural frequencies and the steady state response of a decoupled damped forced two degrees of freedom system. 10ä1 + 2q1 20q1 10 cos t; 10q2 +4q2 + 40q2 10 cos t
Answers: 3
question
Engineering, 04.07.2019 18:20
An open feedwater heater operates at steady state with liquid entering at inlet 1 with t? = 40°c and pl = 1 .2 mpa. water vapor att2-200°c and p2 = 1.2 mpa enters at inlet 2. saturated liquid water exits with a pressure of pa 1.2 mpa. neglect heat transfer with the surroundings and all kinetic and potential energy effects, determine the mass flow rate of steam at inlet 2 if the mass flow rate of liquid water at inlet 1 is given as 2 kg/s.
Answers: 3
question
Engineering, 04.07.2019 19:20
The quality is zero at a)-the saturated vapour state b)-the saturated liquid state c)-the saturated liquid-vapour mixture state d)-none of the states in the other answers
Answers: 3
You know the right answer?
A temperature measurement system was used to measure the temperature of gases exiting a heating unit...
Questions
question
Biology, 30.11.2020 18:50
question
Mathematics, 30.11.2020 18:50
Questions on the website: 13722361