subject
Engineering, 22.08.2020 17:01 mochoa4

What one test(not using the semicarbazone or 2,4-DNP derivatives) could be used to differentiate between the following pairs? Describe what you would observe. a. 2-Pentanone and 3-pentaone
b. Pentanal and 3-pentanone
c. 1-Propanol and 2-propanol
3. Indicate which of the following will give a positive iodoform test:.
acetone 2-pentanone 3-pentanone cyclohexanone
2-methylcyclohexanone ethanol 1-propoanol 2-propanol
t-butyl alcohol acetaldehyde propionaldehyde
4. An unknown compound's semicarbazone melts at 162-165 degree C. The compound does not give a silver mirror in the Tollens' test. On reaction with KI/I_2, NaOH/H_2O no straw yellow precipitate forms. Identify the unknown. Explain your reasoning.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Afluid flows with a velocity field given by v=(x/t)i.. determine the local and convective accelerations when x=3 and t=1.
Answers: 2
question
Engineering, 04.07.2019 18:10
Which of the following controllers anticipates the future from the slope of errors over time? a)-proportional b)-on/off c)-integral d)-derivative.
Answers: 2
question
Engineering, 04.07.2019 18:20
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
question
Engineering, 04.07.2019 18:20
For a gate width of 2 m into the paper, determine the force required to hold the gate abc at its location.
Answers: 1
You know the right answer?
What one test(not using the semicarbazone or 2,4-DNP derivatives) could be used to differentiate bet...
Questions
question
Health, 18.10.2020 15:01
question
English, 18.10.2020 15:01
question
Mathematics, 18.10.2020 15:01
Questions on the website: 13722363