subject
Engineering, 21.09.2020 14:01 pluto82

As the junior engineer at the Mesabi Range Hydraulic Engineering Company located in Ely, Minnesota, you have been tasked with designing a new irrigation canal that will be used by the English Pea Farmers Cooperative of Northern Minnesota. The canal will run from Basswood Lake to the pea fields located just south of town. The canal is to be 22 miles in length, unlined, excavated in stiff clay and must handle a flow rate of 13.15 m3/s over a slope of 0.2%. Your Boss wants you to calculate the necessary canal parameters and to also determine if the canal will fit within the 85-foot wide right-of-way established by the Lake County land-use office

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
You know the right answer?
As the junior engineer at the Mesabi Range Hydraulic Engineering Company located in Ely, Minnesota,...
Questions
question
Arts, 26.04.2021 21:30
question
Mathematics, 26.04.2021 21:30
question
Mathematics, 26.04.2021 21:30
question
Chemistry, 26.04.2021 21:30
Questions on the website: 13722367