subject
Engineering, 13.10.2020 03:01 richardcarmona54

2. Compare the heat loss in W from two windows of a room, one having a single sheet of glass 4 mm thick while the other has two sheets of glass, 2 mm thick each, separated by 2 mm of air. The second window is called a thermopane. The window sizes are 1.5 m × 2 m. The air temperature in the room is 23°C and the outside temperature is -10°C. The average value of the thermal conductivity of glass is 0.96 W/m·K and that of air is 0.0257 W/m·K over this temperature range of interest. The heat transfer coefficient corresponding to slower moving air inside the room is 5 W/m2·K and that of the faster moving air outside is 25 W/m2·K. Consider the thin layer of air between the glass sheets to be stagnant.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
question
Engineering, 04.07.2019 18:20
Asolid cylinder is concentric with a straight pipe. the cylinder is 0.5 m long and has an outside diameter of 8 cm. the pipe has an inside diameter of 8.5 cm. the annulus between the cylinder ad the pipe contains stationary oil. the oil has a specific gravity of 0.92 and a kinematic viscosity of 5.57 x 10-4 m2/s. most nearly, what is the force needed to move the cylinder along the pipe at a constant velocity of 1 m/s?
Answers: 3
question
Engineering, 04.07.2019 19:10
Asteel wire of 2 mm diameter is fixed between two points located 2 m apart. the tensile force in the wire is 250n, if its density of steel is given by 7830 kg/m3 the fundamental frequency of vibration hz? ?
Answers: 3
question
Engineering, 04.07.2019 19:20
Aseries piping system conveys methyl alcohol. the system consists of 70 m of 1- nominal pipe follow by 50 m of 2-nominal pipe, both schedule 40 commercial steel. the 1-nominal pipe contains 3 90° elbows (regular) anda fully open gate valve, all threaded. the pressure drop through the system is 150 kpa. determine the volume flow rate through the system that is horizontally laid.
Answers: 1
You know the right answer?
2. Compare the heat loss in W from two windows of a room, one having a single sheet of glass 4 mm th...
Questions
question
Mathematics, 05.11.2020 02:10
question
Mathematics, 05.11.2020 02:10
question
Mathematics, 05.11.2020 02:10
question
Mathematics, 05.11.2020 02:10
Questions on the website: 13722361